Deskripsi Singkat | Fluke quality is always within your reach
Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.
600 V Cat III safety rating
50% bigger display with bright white backlight
Voltage, resistance, continuity, capacitance
Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function Range Resolution Accuracy
AC volts (40 Hz to 500Hz)1 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3
DC volts 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3
Capacitance3 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5
AC current μA (40 Hz to 400 Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3
AC current mA (40 Hz to 400 Hz) 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3
AC current A (40 Hz to 400 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3
DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3
DC current A 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc, 50 Hz or 60 Hz –
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz –
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz –
1 106 V Hz Max
|
Kategori Produk | |
Dukungan Kurir | |
Bank Transfer |
rek: 1781.2705.18
Rek:118 000 7389 603
|
Bagikan ke | |

TOKO MARGA SETIA SURVEY
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS Magellan, Alat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name : tatang survey
Alamat : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email : tatangms409@gmail.com
Telp : 082124100046
WhatsApp :082124100046
www.margasetiaonleneshoop.com
Fluke quality is always within your reach
Your job requires that you have a rugged, reliable and accurate
digital multimeter. The Fluke 15B+ digital multimeter does all that and
more. Easy to use with one hand, even with gloves on, the Fluke 15B+
offers everything you need.
- 600 V Cat III safety rating
- 50% bigger display with bright white backlight
- Voltage, resistance, continuity, capacitance
- Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %.
Accuracy specifications take the form of: ±(% of Reading + Number of
Least Significant Digits).
| General Specifications |
| Maximum voltage between any terminal and earth ground |
1000 V |
| Display (LCD) |
4000 counts, updates 3/sec |
| Battery type |
2 AA, NEDA 15A, IEC LR6 |
| Battery life |
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.) |
| Temperature |
| Operating |
0 °C to 40 °C |
| Storage |
-30 °C to 60 °C |
| Relative Humidity |
| Operating humidity |
Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C |
| 40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C |
| Altitude |
| Operating |
2000 m |
| Storage |
12,000 m |
| Temperature coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
| Fuse protection for current inputs |
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only. |
| Size (HxWxL) |
183 x 91 x 49.5 mm |
| Weight |
455 g |
| IP rating |
IP 40 |
| Safety |
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 |
| Electromagnetic environment |
IEC 61326-1: Portable |
| Electromagnetic compatibility |
Applies to use in Korea only |
| Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes. |
| Function |
Range |
Resolution |
Accuracy |
| AC volts
(40 Hz to 500Hz)1 |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
1.0 % + 3 |
| DC volts |
4.000 V
40.00 V
400.0 V
1000 V |
0.001 V
0.01 V
0.1 V
1 V |
0.5 % + 3 |
| AC millivolts |
400.0 mV |
0.1 mV |
3.0 % + 3 |
| DC millivolts |
400.0 mV |
0.1 mV |
1.0 % + 10 |
| Diode test2 |
2.000 V |
0.001 V |
10% |
| Resistance
(Ohms) |
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ |
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ |
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3 |
| Capacitance3 |
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF |
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF |
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5 |
| AC current μA
(40 Hz to 400 Hz) |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
| AC current mA
(40 Hz to 400 Hz) |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
| AC current A
(40 Hz to 400 Hz) |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
| DC current μA |
400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
| DC current mA |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
| DC current A |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
| Backlight |
Yes |
| 1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead
capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF
range). |
| Function |
Overload Protection |
Input Impedance (Nominal) |
Common Mode Rejection Ratio |
Normal Mode Rejection Ratio |
| AC volts |
1000 V 1 |
>10 MΩ <100 pF |
>60 dB at dc,
50 Hz or 60 Hz |
– |
| AC millivolts |
400 mV |
>1MΩ, <100 pF |
>80 dB at 50 Hz or 60 Hz |
– |
| DC volts |
1000 V 1 |
>10 MΩ <100 pF |
>100 dB at dc,
50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
| DC millivolts |
400 mV |
>1MΩ, <100 pF |
>80 dB at 50 Hz or 60 Hz |
– |
| 1 106 V Hz Max |