Alamat : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email : tatangms409@gmail.com
Telp : 082124100046
WhatsApp :082124100046
www.margasetiaonleneshoop.com
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for HVAC (heating ventilation air
conditioning) troubleshooting. The Fluke 116 was specifically designed
for the HVAC professional. It has everything needed in an HVAC meter
including temperature and microamp measurements to quickly troubleshoot
problems with HVAC equipment and flame sensors.
Also check out the Fluke 114 Electrical Multimeter, the Fluke 115
Multimeter, and the Fluke 117, the Electrician’s Multimeter with
Non-contact voltage.
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
Accuracy Specifications |
DC millivolts |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.00 V / 0.1 V |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
Auto volts |
Range: |
600.0 V |
Resolution: |
0.1 V |
Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
|
AC millivolts1 true-rms |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.0 V / 0.1 V |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity |
Range: |
600 Ω |
Resolution: |
1 Ω |
Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
Ohms |
Range/Resolution: |
600.0 Ω / 0.1 Ω |
Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
Accuracy: |
0.9 % + 1 |
Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
Accuracy: |
1.5 % + 2 |
|
Diode Test |
Range/Resolution: |
2.000 V / 0.001 V |
Accuracy: |
0.9% + 2 |
|
Capacitance |
Range/Resolution: |
1000 nF / 1 nF |
Range/Resolution: |
10.00 μF / 0.01 μF |
Range/Resolution: |
100.0 μF / 0.1 μF |
Range/Resolution: |
9999 μF / 1 μF |
Range/Resolution: |
100 μF to 1000 μF |
Accuracy: |
1.9% + 2 |
Range/Resolution: |
> 1000 μF |
Accuracy: |
5% + 20% |
|
LoZ capacitance |
Range: |
1 nF to 500 μF |
Accuracy: |
10% + 2 typical |
|
Temperature2 (Type-K thermocouple) |
Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
Accuracy: |
1% + 102 |
Range/Resolution: |
-40 °F to 752 °F / 0.2 °F |
Accuracy: |
1% + 182 |
|
AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution: |
600.0 μA / 0.1 μA |
Accuracy: |
1.0% + 2 |
|
DC μamps |
Range/Resolution: |
600.0 μA / 0.1 μA |
Accuracy: |
1.0% + 2 |
|
Hz (V or A input)2 |
Range/Resolution: |
99.99 Hz / 0.01 Hz |
Range/Resolution: |
999.99 Hz / 0.1 Hz |
Range/Resolution: |
9.999 Hz / 0.001 Hz |
Range/Resolution: |
50.00 Hz / 0.01 Hz |
Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications |
Size |
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
|
Weight |
|
Warranty |
|
Specifications |
Maximum voltage between any terminal and earth ground |
|
Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
|
Display |
Digital: |
6,000 counts, updates 4 per second |
|
Bar graph |
|
33 segments, updates 32 per second |
|
Operating Temperature |
|
Storage Temperature |
|
Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery Life |
|
400 hours typical, without backlight |
|