Jual Digital Multimeter, Fluke, Fluke 17B+

Fluke 17B+

TOKO MARGA SETIA SURVEY
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS Magellan, Alat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name       : tatang survey
Alamat      : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email        : tatangms409@gmail.com
Telp          : 082124100046
WhatsApp  :082124100046
www.margasetiaonleneshoop.com

Fluke quality is always within your reach
Your job requires that you have a rugged, reliable and accurate digital multimeter.  The Fluke 17B+ digital multimeter does all that and more.  Common basic electrical measurements plus temperature, frequency and duty cycle.  Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need
  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Over-voltage indicator
  • Frequency and temperature measurement
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold
  • General Specifications
    Maximum voltage between any terminal and earth ground 1000 V
    Display (LCD) 4000 counts, updates 3/sec
    Battery type 2 AA, NEDA 15A, IEC LR6
    Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
    Temperature
    Operating 0 °C to 40 °C
    Storage -30 °C to 60 °C
    Relative Humidity
    Operating humidity Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C
    40 MΩ range ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C
    Altitude
    Operating 2000 m
    Storage 12,000 m
    Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only.
    Size (HxWxL) 183 x 91 x 49.5 mm
    Weight 455 g
    IP rating IP 40
    Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
    Electromagnetic environment IEC 61326-1: Portable
    Electromagnetic compatibility Applies to use in Korea only
    Class A equipment (industrial broadcasting & communication equipment)1 1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
     
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function Range Resolution Accuracy
AC volts (40 Hz to 500Hz)1 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3
DC volts 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3
Capacitance3 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5
Frequency1 Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz 0.1 % + 3
Duty Cycle1 1 % to 99 % 0.1 % 1 % typical 4
AC current μA (40 Hz to 400 Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3
AC current mA (40 Hz to 400 Hz) 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3
AC current A (40 Hz to 400 Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3
DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3
DC current A 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3
Temperature 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C 0.1C 2 % ± 1 °C ± 2 °C 9 % ± 2 °C
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc, 50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz