TOKO MARGA SETIA SURVEY
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS MagellanaAlat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name : tatang survey
Alamat : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email : tatangms409@gmail.com
Telp : 082124100046
WhatsApp :082124100046
www.margasetiaonleneshoop.com
Berdagang alat- alat Kelautan, Alat Selam, Perahu Karet,Alat Keselamatan,
GPS Garmin, GPS MagellanaAlat Survey, Alat Ukur dan Aksesoris Alat Ukur.
Current Meter.Anemometer ,Anemometer Wireless,Weather station
Untuk keterangan, nego harga dan informasi produk lainnya, hubungi :
Name : tatang survey
Alamat : Jl .H.Kelik No.20 RT.03 / RW.08 Kelapa Dua Kebon Jeruk Jakarta Barat
Email : tatangms409@gmail.com
Telp : 082124100046
WhatsApp :082124100046
www.margasetiaonleneshoop.com
The Fluke 179 – Just One of Fluke’s Trusted Tools
Fluke builds the most trusted tools in the world, and that means more than just the Fluke 179. If you work with the HVAC equipment, need a small meter for small spaces, or work in the electrical installer’s and repairman’s world, check out the full family of Fluke digital multimeters.- Manual and automatic ranging
- Display Hold and Auto Hold
- Frequency and capacitance measurements
- Resistance, continuity and diode measurements
- Temperature measurements (179)
- Min-max-average recording
- Closed case calibration through front panel
- Ergonomic case with integrated protective holster
All inputs are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V., CSA, and TÜV listed
Specification
Specifications | ||
Voltage DC | Accuracy1 | ±(0.09% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
Temperature | Accuracy1 | ±(1.0% + 10) |
Max. resolution | 0.1°C | |
Range | -40°C / 400°C | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 50°C) | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV |
Posting Komentar