Environmental Specifications | |
---|---|
Diameter of measurable conductor | 0.177 or 4.5 mm max |
Operating temperature | -10 to 50 ºC |
Storage Temperature | -25 to 60ºC |
Operating Humidity | < 90% @ <30 ºC, < 75% @ 30 to 55ºC |
Operating Altitude | 0 to 2000 m |
IP Rating | IP 40 |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) |
Weight | 410 g, (14.4 oz) |
Vibration | Random 2 g, 5 to 500 Hz |
Shock | 1 meter drop test (except the jaw) |
EMI/RFI | Meets EN61326-1 Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. |
Temperature Coefficient | 0.01% ºC (<18ºC or > 28) |
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms |
Warranty | Three years for electronics one year for cable and clamp assembly |
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
Here are some specific ways the Fluke 773 Clamp Meters will help you:
Milliamp Clamp Features | Application | How it saves time and money |
---|---|---|
Measure mA signals for PLC and control system analog I/O without breaking the loop. | Measures low level dc current | Correlate process indication with real physical value |
Measure output signals from transmitters without breaking the loop | Maintain and troubleshoot process and automation equipment without breaking the loop | No disruption to the process |
Detachable clamp with extension cable | Measurements in tight locations | Enables measurements in difficult situations |
Source, simulate and measure mA signals in circuit (break the loop) | Confirm non-contact measurement. ve the next tool in hand for troubleshooting (source simulate) | Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurement |
Source and measure VDC | Troubleshoot voltage input and output devices. | Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders |
4 to 20 mA In/out | Dual channel mA source and measurement for troubleshooting | Source 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals. |
4 to 20 mA scaled output | Scaled mA output provides a mA signal output representative of the measured mA value | Connect a logging DMM and log the mA signal without breaking the loop |
Loop power supply | Power a transmitter | Substitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting. |
Dual backlit display with both mA measurement and percent of 4 to 20 mA span | Clear measurement presentation | Allows quick measurement evaluation |
Measurement Spotlight | Illuminates hard to see wires in dark enclosures | Measurement process is easier and quicker |
Measure up to 99.9 mA range non-contact | Wide range of measurements | Measures 10 to 50 mA signals in older control systems |
Automatic power off | After 15 minutes and 2 minute automatic off for backlight and spotlight | Saves battery life |
- Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- Automatically change the 4 to 20 mA output for remote testing
- DC voltage measurement to verify 24V power supplies or voltage I/O signals
- Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
- Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
- Enables milliamp signal logging to a separate logging device without breaking the loop
- Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
- mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
- Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
- Voltage output linear ramp or 25% step output
What’s the difference between the 77X models?
Fluke-771 | Fluke-772 | Fluke-773 | |
---|---|---|---|
. | Non-contact mA loop measurement | Integrated mA loop troubleshooting | Advanced process troubleshooting |
mA measure, jaw | |||
mA measure, in circuit | . | ||
Loop power | . | ||
mA source | . | ||
DCV measure | . | . | |
DCV source | . | . | |
mA scaled output | . | . | |
mA in / out | . |